(7) An experiment to measure the rate of
aerobic respiration of woodlice using a respirometer and how it varies with
temperature
This describes how to investigate the
rate of respiration of small organisms like woodlice (an
arthropod) by measuring their
rate of uptake of oxygen that is being used in the organisms metabolism.
A respirometer is a device
designed to measure the rate of consumption of oxygen by a living organism.
The rate of oxygen depletion in
the air e.g. cm3/min by gas volume or mm/min on some
scale is taken as a measure of the rate of respiration.
You can also use germinating peas or
germinating beans to investigate the effect of temperature on the rate of
their respiration. Germinating seeds need to respire to
provide energy from them to grow and develop into the plant.
Experimental set up
for this investigation - explaining the respirometer system
A
boiling tube is set up in a thermostated water bath to control the
temperature of the experiment - you should use a thermometer to
accurately monitor the temperature of the water. A syringe containing air and a manometer
are connected via glass tubing through a rubber bung to the boiling
tube. Together with the soda lime this set up is called a respirometer.
A manometer is a device to measure
pressures. A common simple manometer consists of a U shaped tube of
glass filled with some liquid - in this case coloured water NOT
poisonous mercury! A ruler scale is placed in between the arms of the U
tube so the difference in heights of the liquid can be measured in both arms.
The syringe is used to set the level
of the liquid in the manometer and refresh the air between experiments.
At the bottom of the boiling tube soda lime granules are placed to
absorb carbon dioxide given
out by the respiring woodlice. On top of the soda lime is a wad of
cotton wool to prevent contact with the woodlice - they would be harmed
by the strongly alkaline soda lime - an ethical point when using live
animals in experiments.
The live woodlice are carefully
placed on the cotton wool and the rest of the apparatus of the
respirometer is carefully assembled so that boiling tube is vertical in
the water bath.
Experimental notes
Note 1: The reduction in volume
shows a gas is being removed from air, and that gas is oxygen. There
would be no change in volume without the soda lime - the volume of CO2
formed would equal the volume of O2 used. But, since
the soda lime removes the carbon dioxide given out by the organism's
respiration, there is no confusion that the gas volume reduction is due
to the uptake of oxygen by respiration and the liquid in the manometer
moves towards respiring organism in the test tube.
Note 2: The right-hand limb of
the manometer can be connected to a 2nd control test tube set up in the
same way as the respiring organism test tube. This test tube is
connected to the manometer and a tap is fitted instead of the syringe. A
control test tube helps check that movement of the fluid in the
manometer is only caused by the respiration of the organism.
Note 3: Instead of soda lime
granules, you can use cotton wool soaked in a concentrated solution of
an alkali e.g. sodium hydroxide or potassium hydroxide.
Respirometer
investigation procedure
(a) The water bath, and boiling tube
without woodlice in the boiling tube, are left for a short time until
the temperature of the water bath has settled down to your desired start
temperature e.g. 20oC.
(b) The woodlice are then quickly
placed in the boiling tube, connect everything up as shown in the
diagram.
(c) The syringe is used to equate the
liquid levels in the manometer, preferably to zero difference in height
(R1 = 0).
R1 doesn't have to be zero as
long as you carefully read and record readings in both limbs of the
manometer at the start and end of the respiration experiment.
(d) Let the woodlice respire for a
fixed time.
As they respire and use up oxygen, carbon dioxide is
produced, which is absorbed by the soda lime, decreasing the volume of
air.
(e) As the air volume decreases, it
temporarily reduces the pressure in the boiling tube containing
the respiring organism, therefore, to
maintain the constant external pressure ('fair test'), the liquid moves up the left limb of the
U tube manometer.
(f) After a set time, you read the
two levels to determine R2 (left reading - right reading in the U
tube).
The total distance moved by the
liquid = the difference between the two readings, R2 - R1, and this
gives you a relative measure of the rate of respiration.
(technically it doesn't matter if
R1 isn't zero at the start, as long as you subtract the initial
differential reading R1 from R2, you obtain the actual numerical change desired.)
(g) You then repeat (a) to (f) with
the same woodlice, at a higher temperatures going up 5o at
time up to 50oC.
You need to replenish the air in
the test tube and move the manometer liquid down and away from the
test tube.
The greater the rate of movement
of the coloured liquid in the thermometer, the greater the rate of
respiration
Further experimental notes:
Theoretically, because the
syringe is also calibrated, the syringe 'plunger' can be carefully
depressed to return the manometer liquid levels to their
original readings.
The volume of oxygen used =
final syringe volume - initial syringe volume (e.g. in cm3).
This allows you to calculate
the woodlice rate of respiration in cm3/min.
OR, you can just use the
manometer level readings as a relative measure of respiration
e.g. mm/min.
Ethical note:
The woodlice should not be
used at sufficiently high temperatures that they die.
The woodlice should not be
left in the respirometer too long so that they run out of oxygen
and die.
After the experiment they
should be released back into their natural outside habitat.
The woodlice should be
allowed to come into contact with the soda lime or any other
harmful chemical used to absorb the carbon dioxide.
Results, analysis and conclusions
As described above, the relative rate
of respiration is measured as the rate of oxygen consumption in mm/min
or cm3/min.
From your data table of results you can plot a graph of rate of respiration versus temperature.
You should find initially the rates
increases, passes through an optimum at ~35-40oC and then decreases.
steadily as the temperature goes higher.
This is typical of the behaviour
of enzyme controlled reactions - which includes the metabolic
chemistry of respiration.
Initially, as with any chemical
reaction, the rate increases with increase in temperature.
However, as the temperature rises the
enzymes become denatured and the rate of respiration will fall and the
organism will be harmed.
This is not acceptable - unethical,
so you should not raise the temperature too high and obtain just the
first half of the graph above.
However, there is no reason why you
cannot do higher temperature experiments with respiring seeds and see if
you can get the full graphical picture of rates of respiration versus
temperature.
Key points -
experiment to measure the rate of aerobic respiration of woodlice
using a respirometer
Based
on the syllabus-specifications for students taking the AQA, Edexcel and
OCR GCSE level biology examinations (~US grades 9-10).
Experiment: Measuring Aerobic
Respiration in Woodlice Using a Respirometer
This experiment investigates
how aerobic respiration in woodlice is affected by temperature, using a
respirometer to measure the
rate of oxygen uptake.
Apparatus
-
Respirometer (e.g. U-tube
or capillary type with scale)
-
Live woodlice
-
Control tube with glass
beads or dead woodlice (equal mass)
-
Potassium hydroxide or
soda lime (to absorb CO2)
-
Syringes or rubber bungs
-
Vaseline (to create
airtight seals)
-
Stopwatch
-
Water bath or incubator
(to control temperature)
-
Ruler or calibrated scale
Method Overview
-
Assemble the
respirometer:
-
Place a known number
of live woodlice into one chamber.
-
Use the same mass of
non-respiring material (e.g. glass beads) in the control chamber.
-
Add potassium
hydroxide or soda lime to absorb any CO2 produced, ensuring
that volume changes are due to O2 consumption only.
-
Seal the system:
-
Place the
apparatus at a set temperature:
-
Record results:
-
Measure the
distance the coloured fluid moves over a fixed time (e.g.
every 5 minutes for 20 minutes).
-
Repeat at
different temperatures (e.g. 10oC, 20oC, 30oC, 40oC).
Variables
Calculations
To calculate the
rate of respiration:
Rate = Volume of O2
absorbed (e.g. mm3) / {Time (e.g. minutes)
If using a capillary tube
with known cross-sectional area:
Volume = π r2
h where r is the
radius of the capillary and h is the distance the dye moves.
Interpreting Results
-
As temperature
increases, the rate of respiration typically increases,
due to higher enzyme activity.
-
Beyond the optimum
temperature, the rate decreases as enzymes may become
denatured.
-
The control tube helps
ensure that changes are due to respiration, not
temperature effects on air pressure or apparatus.
Summary
-
Woodlice respire
aerobically, taking in
oxygen.
-
A respirometer
measures oxygen uptake as an indirect measure of respiration
rate.
-
CO₂ is absorbed,
so any volume change reflects only oxygen used.
-
Temperature
affects respiration,
usually increasing the rate up to an optimal point.
Keywords, phrases and learning objectives for this section on respiration
Be able to describe experiments to measure the rate of aerobic
respiration of woodlice using respirometer at different temperatures.
In describing the method to measure the rate of
aerobic respiration, you need to know the details of the
respirometer
apparatus from a diagram and outline the procedure, data collection
and calculate the relative rate of respiration.
WHAT NEXT?
TOP OF PAGE
INDEX
of biology notes on respiration
INDEX of all my BIOLOGY NOTES
This is a BIG website, so try using the [SEARCH
BOX], it maybe quicker than the many indexes!
email doc
brown - comments - query?
Basic Science Quizzes for
UK KS3 science students aged ~12-14, ~US grades 6-8
Biology * Chemistry
* Physics for UK
GCSE level students aged ~14-16, ~US grades 9-10
Advanced Level Chemistry
for pre-university age ~16-18 ~US grades 11-12, K12 Honors
Find your GCSE/IGCSE
science course for more help links to all science revision notes
Website content © Dr
Phil Brown 2000+. All copyrights reserved on Doc Brown's biology
revision notes, images, quizzes, worksheets etc. Copying of website
material is NOT permitted. Exam revision summaries and references to
science course specifications are unofficial. Explaining the importance of
investigation using woodlice to measure rate of respiration at
difference temperatures using respirometer
in GCSE biology, What you need to know about investigation using
woodlice to measure rate of respiration at difference temperatures using
respirometer for IGCSE biology,
Explaining the use of investigation using woodlice to measure rate of
respiration at difference temperatures using respirometer knowledge in GCSE biology, Examples of
investigation using woodlice to measure rate of respiration at
difference temperatures using respirometer explained
for GCSE biology exams, What is
the significance of investigation using woodlice to measure rate of
respiration at difference temperatures using respirometer in studying for biology exams, What is the use of
investigation using woodlice to measure rate of respiration at
difference temperatures using respirometer ? Describing and
explaining the theory of investigation using woodlice to measure rate of
respiration at difference temperatures using respirometer, revision preparation for AQA GCSE biology,
Edexcel GCSE biology, OCR GCSE biology. Website content © Dr
Phil Brown 2000+. All copyrights reserved on Doc Brown's biology revision notes, images,
quizzes, worksheets etc. Copying of website material is NOT
permitted. Exam revision summaries and references to science course specifications
are unofficial. These revision notes on investigation using
woodlice to measure rate of respiration at difference temperatures using
respirometer are suitable for AQA gcse
biology,
investigation using woodlice to measure rate of respiration at
difference temperatures using respirometer revision notes for Edexcel gcse biology,
investigation using woodlice to measure rate of respiration at
difference temperatures using respirometer revision notes for OCR gcse Gateway science biology,
investigation using woodlice to measure rate of respiration at
difference temperatures using respirometer revision notes for OCR 21st Century
science biology, investigation using woodlice to measure rate of
respiration at difference temperatures using respirometer revision notes WJEC GCSE biology,
investigation using woodlice to measure rate of respiration at
difference temperatures using respirometer revision
notes for CCEA gcse biology, investigation using woodlice to measure
rate of respiration at difference temperatures using respirometer revision notes for CIE Cambridge IGCSE
biology exams.
Explaining importance of
method details of an experiment to measure the rate of respiration of
woodlice
in GCSE level biology, What you need to know about method details of an
experiment to measure the rate of respiration of woodlice for
GCSE level
biology,
Explaining use of method details of an experiment to measure the rate of
respiration of woodlice knowledge in GCSE level biology, Examples of
method details of an experiment to measure the rate of respiration of
woodlice
explained when studying GCSE level biology, What is the significance of
method details of an experiment to measure the rate of respiration of
woodlice in GCSE level biology, describing
explaining theory of method details of an experiment to measure the rate
of respiration of woodlice when studying GCSE level biology, exam revision
notes for method details of an experiment to measure the rate of
respiration of woodlice, online help for understanding method details of
an experiment to measure the rate of respiration of woodlice in GCSE
biology, what do I need to learn about method details of an experiment
to measure the rate of respiration of woodlice? what do I need to know about
method details of an experiment to measure the rate of respiration of
woodlice for GCSE biology exams, how to prepare for questions on method
details of an experiment to measure the rate of respiration of woodlice in GCSE
biology examination?
SITEMAP Website content © Dr
Phil Brown 2000+. All copyrights reserved on Doc Brown's biology revision notes, images,
quizzes, worksheets etc. Copying of website material is NOT
permitted. Exam revision summaries and references to science course specifications
are unofficial.
INDEX
of biology notes on respiration